Воздухоочиститель с функцией увлажнения MCK55W

  • Эффективность против респираторных вирусов оценена Институтом Пастера де Лилля
  • Чистый воздух благодаря подходу Daikin ‘Улавливай и очищай’ при разложении вредных веществ
  • Высокопроизводительный фильтр HEPA без необходимости замены в течение 10 лет
  • Один из самых бесшумных воздухоочистителей на европейском рынке

Описание

          MCK55WVM
Type Humidifying air purifier
Application Floor standing type
Casing Colour White
Dimensions Unit Height mm 700
Width mm 270
Depth mm 270
Weight Unit kg 9.5
Applicable room area 41 (1), 82 (2)
Air purifying operation Power input Turbo kW 0.056
M kW 0.017
L kW 0.010
Silent kW 0.007
Humidifying operation Power input Turbo kW 0.058
M kW 0.019
L kW 0.014
Silent kW 0.011
Water tank capacity l 2.7
Sound pressure level Air purifying operation Turbo dBA 53.0
Medium dBA 39.0
Low dBA 29.0
Silent dBA 19.0
Humidifying operation Turbo dBA 53.0
 Medium  dBA 39.0
Low dBA 33.0
Silent dBA 25.0
Fan Air flow rate Air purifying operation Turbo m³/h 330
Medium m³/h 192
Low m³/h 120
Silent m³/h 54
Humidifying operation Turbo m³/h 330
Medium m³/h 192
Low m³/h 144
Silent m³/h 102
Dust collecting method Electrostatic HEPA filter
Deodorizing method Flash streamer + Deodorizing catalyst
Standard Accessories Remote control lid 1
Remote control holder 1
Electrostatic HEPA filter 1
Humidifying filter 2
Deodorising filter 1
Operation manual 1
Caster 4
Power cord m 1.8
Power supply Phase 1~
Frequency Hz 50/60
Voltage V 220-240/220-230
Running current Air purifying operation Turbo A 0.50
Medium A 0.19
Low A 0.12
Silent A 0.09
Humidifying operation Turbo A 0.50
Medium A 0.20
Low A 0.15
Silent A 0.13
Notes (1) - The applicable room area is appropriate for operating the unit of maximum fan speed (HH). Applicable room area indicates  the space where a certain amount of dust particles can be remover in 30 minutes. (JEM 1467)
(2) - Converted to NRCC standards from test values in accordance with JEM1467.
(3) - Converted to CADR standards from test values in accordance with JEM1467.
(4) - Humidification amount changes in accordance with indoor and outdoor temperature and humidity. Measurement condition: 20°C in temperature, 30% in humidity.
(5) - Operating sound levels are the average of values measured at 1m away from the front, left, right and top of the unit. (These are equal to the values in an anechoic chamber)
(6) - Electrostatic HEPA filter and humidifying filters are attached in the unit.
(7) - Requirements according to JEM1467.